Throughput
  • Up to 133 EMIT® tests per hour with two reagents
  • Up to 65 EMIT® tests per hour with three reagents 

Reagent system
  • EMIT reagent rotor — with 13 positions for 14 mL bottles and 13 positions for 28 mL bottles
  • All positions in both rotors can be assigned as R1, R2, and R3
  • The reagent rotor compartment is cooled to 8–12°C (absolute up to 25°C ambient temperature)
  • Reagent volumes:
       – Reagent 1 volume 110–399 μL
       – Reagent 2 volume 10–289 μL
       – Reagent 3 volume 10–289 μL
  • Aspirated reagents are heated, with level detector and integrated stirrer
Sample system – providing semi-continuous
loading
  • Sample rotor contains:
       – 50 positions for barcoded tubes
       – 12 positions for tubes without barcodes
       – 1 blank and 1 washing position
  • Primary tubes (13 or 16 mm OD)
  • Positions can contain 5 mL or 10 mL primary tubes or sample cups
  • Sample volume 1 – 30 µL per test, programmable in steps of 0.1 µL
  • Sample probe with level detection and integrated stirrer
Pipetting system
  • Flex Fluidics syringes
  • Reagent syringe 1000 μL
  • Sample syringe 100 μL
Cuvette rotor
  • Semi-disposable rotor with 48 cuvettes, path length 6.8 mm
  • Minimum measuring volume 200 μL
  • Measuring temperature 37°C controlled by Peltier elements
Washing units
  • Cuvette rinsing with 4 x 500 μL of treated water:
       – The unit is equipped with liquid sensors
       – Waste is separated into diluted and
          concentrated waste

        – Cuvettes are dried before use

Light sourceQuartz-iodine lamp 12 V – 20 W
Wavelength range
  • Automatic wavelength selection by an 8-position filterwheel (340, 415, 505, 546, 570, 600, 660, 700 nm)
  • Half bandwidth 8 to 12 nm
Photometric rangeAbsorbance -0.1 to 3.0
Ambient temperature
  • 15–32°
  • Relative humidity 15–85% (non condensing)
Calculation modes
  • Linear regression
  • Modified cubic spline
  • Syva® 4 parameter logit log
Quality control
  • Up to 6 controls per parameter (up to 12 controls programmable per rotor configuration)
  • Westgard rules
  • Levey-Jennings plots
Computer
  • CPU: Intel Celeron M 575 2 GHz
  • Touchscreen monitor: 15.6 inch, 1366 x 768 pixels
  • Ports: 1 serial, 4 USB, and 1 ethernet port       
Printer
  • The application supports one printer
  • Most printers supported by WINDOWS can be connected
Barcode reader (option)

The Viva-ProE™ is equipped with an internal barcode reader to read barcoded sample tubes. An optional hand-held barcode reader is available.

LanguagesEnglish, French, German, Italian, Spanish; others on request
Dimensions

Width: 125 cm/49.2 in

Depth: 62 cm/24.4 in

Height, excl monitor: 75 cm/29.5 in

Weight: approx. 93 kg/205 lbs (excl. monitory

arm and panel PC)

 

Bu web sayfasında gösterilen ürünler/özellikler her ülkede piyasada bulunmamaktadır. Mevzuata bağlı nedenlerle gelecekte bulunabileceği garanti edilemez. Lütfen daha fazla bilgi için yerel Siemens organizasyonuyla iletişime geçiniz.

Bu bilgi yardımcı oldu mu?
Yanıtınız için teşekkür ederiz
Yorumunuzda sayı ve/veya '@' işareti olduğunu fark ettik. Sizinle iletişime geçmemiz için telefon numarası ya da e-posta adresi girmeye çalışıyorsanız lütfen bizimle e-posta formumuz aracılığıyla iletişime geçiniz.

Not: Doğrudan kişisel bir yanıt almak için lütfen bizimle e-posta formumuz üzerinden iletişime geçiniz.

Teşekkür ederiz